by Jim
(Cape Coral FL.)
Will not start from key switch from helm have power on the white wire. Gray wire is energizing with key switch out. Neutral safety switch rings out good. Black and green which are grounds are working corectly in the stop and e-stop circuit. 30amp and 60amp fuses on motor are fine. Replaced starter relay. Had it running and tested neutral safety switch and kill switch they functioned correctly. Put everything back together and straighteed up wiring under helm stopped working. Believe bad/correded wire in the helm area. How do I test/ring out the wire in the harness to the ecm/starter relay?